Home
Product Directory
Electrical & Electronics
Optical Fiber, Cable & Wire
Electric Wire & Cable
H05V-R H05V-K H07V-K H07V-R H03VV-F Flexible Copper Conductor Building Wire
Port:
Qingdao, China
Production Capacity:
50000km/Month
Payment Terms:
L/C, T/T, D/P, Western Union, Paypal, Money Gram
People's Cable Group Co., Ltd.
Henan, China
Last Login Date:
Nov 04, 2025
Main Products:
ABC Cable, AAAC, ACSR, ACSR/Aw, Acar, AAC, Acs, Gsw, Electrical/House/Building Wire, Power Cable
Find Similar Products
Product Description
Company Info
Basic Info.
Type
Conductor Type
Solid or Stranded
Application
Overhead, Underground, House and Building
Conductor Material
Copper or Aluminium or Aluminium Alloy
Sheath Material
Insulation Material
Material Shape
Flat & Round
Range of Application
Certification
ISO9001, CCC
Brand
Rmjt
Product Name
Flexible Copper Conductor H05V-R H05V-K H07V-K H07
Voltage
300/300V 300/500V 450/750V
Insulation Color
Red, Black, Yellow, Blue, Green, Grey and So on
Standard
IEC, UL, BS, VDE, AS/NZS or According to You.
Conductor Class
Class 5, Class6
Aerial
0.5~100mm2
Trademark
RMJT
Transport Package
100m/Roll or Bag
Specification
1.5-800mm2
Origin
China
HS Code
8544492100
Product Description
Flexible Copper Conductor H05V-R H05V-K H07V-K H07V-R H03VV-F Building Wire
1.Application:
PVC insulation wires are used for electricity transmission for building, construction, lighting and so on.
2.Standard:
GB/T 5023-2008, BS 6004, IEC 60227, VDE ,UL
3.Specification:
H05V-U Specification
H05V-R Specification
H05V-K Specification
H07V-R Specification
H07V-K Specification
HO3VV-F and AO3VV-F Specification
H03VVH2-F Specification
4.Package:
Packing in plastic reel, paper reel ,wooden drum or as customer's requirement.
5.Our factory:
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
6.Certificate:
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
7.Customer Visit:
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
8.Contact:
Dear friends, welcome to our store. We will provide you with china wholesale market market products, excellent service and reasonable price.Please contact us if have any questions about the product. we will answer the questions carefully.At last,I wish you a pleasant purchase.
Factrory ADD:No.13th,YongDing Road, Goingyi,Zhengzhou city, Henan province, China.
1.Application:
PVC insulation wires are used for electricity transmission for building, construction, lighting and so on.
2.Standard:
GB/T 5023-2008, BS 6004, IEC 60227, VDE ,UL
3.Specification:
H05V-U Specification
| 300/500V,Copper Conductor PVC Insulated Wire | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | Diameter | mm | mm | kg/km |
| 1 X 0.5 | 1 | 0.8 | 0.6 | 2.00 | 8.16 |
| 1 X 0.75 | 1 | 0.97 | 0.6 | 2.17 | 10.71 |
| 1 X 1.0 | 1 | 1.13 | 0.6 | 2.33 | 13.48 |
| 300/500V, Copper Conductor Heat Resistant PVC Insulated Connecting Wire at 90ºC | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | Diameter | mm | mm | kg/km |
| 1 X 0.5 | 1 | 0.8 | 0.6 | 2.00 | 8.16 |
| 1 X 0.75 | 1 | 0.97 | 0.6 | 2.17 | 10.71 |
| 1 X 1.0 | 1 | 1.13 | 0.6 | 2.33 | 13.48 |
| 1 X 1.5 | 1 | 1.38 | 0.7 | 2.78 | 19.70 |
| 1 X 2.5 | 1 | 1.78 | 0.8 | 3.38 | 31.20 |
H05V-R Specification
| 300/500V,Copper Conductor PVC Insulated Wire | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | mm | mm | mm | kg/km |
| 1 X 0.75 | 7 | 0.37 | 0.6 | 2.31 | 11.3 |
| 1 X 1.0 | 7 | 0.43 | 0.6 | 2.49 | 14.2 |
H05V-K Specification
| 300/500V,Copper Conductor PVC Insulated Flexible Connecting Wire | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | Diameter | mm | mm | kg/km |
| 1 X 0.5 | 28 | 0.15 | 0.6 | 2.16 | 8.65 |
| 1 X 0.75 | 40 | 0.15 | 0.6 | 2.40 | 11.22 |
| 1 X 1.0 | 32 | 0.20 | 0.6 | 2.54 | 14.32 |
| 300/500V, Copper Conductor Heat Resistant PVC Insulated Connecting Wire at 90ºC | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | Diameter | mm | mm | kg/km |
| 1 X 0.5 | 28 | 0.15 | 0.6 | 2.16 | 8.65 |
| 1 X 0.75 | 40 | 0.15 | 0.6 | 2.40 | 11.22 |
| 1 X 1.0 | 32 | 0.20 | 0.6 | 2.54 | 14.32 |
| 1 X 1.5 | 30 | 0.25 | 0.7 | 3.00 | 20.58 |
| 1 X 2.5 | 49 | 0.25 | 0.8 | 3.70 | 32.24 |
| 450/750V,Copper Conductor PVC Insulated Wire | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | Diameter | mm | mm | kg/km |
| 1 X 1.5 | 7 | 0.52 | 0.7 | 2.96 | 20.4 |
| 1 X2.5 | 7 | 0.67 | 0.8 | 3.61 | 32.3 |
| 1 X4.0 | 7 | 0.85 | 0.8 | 4.15 | 47.8 |
| 1 X6.0 | 7 | 1.04 | 0.8 | 4.72 | 67.7 |
| 1 X10 | 7 | 1.35 | 1.0 | 6.05 | 113.1 |
| 1 X 16 | 7 | 1.70 | 1.0 | 7.1 | 170.9 |
| 1 X 25 | 7 | 2.14 | 1.2 | 8.82 | 268.5 |
| 1 X 35 | 7 | 2.52 | 1.2 | 9.96 | 362.8 |
| 1 X 50 | 19 | 1.78 | 1.4 | 11.7 | 492.2 |
| 1 X 70 | 19 | 2.14 | 1.4 | 13.5 | 694.2 |
| 1 X 95 | 19 | 2.52 | 1.6 | 15.8 | 959.2 |
| 1 X 120 | 37 | 2.03 | 1.6 | 17.41 | 1197.1 |
| 1 X 150 | 37 | 2.25 | 1.8 | 19.35 | 1472.9 |
| 1 X 185 | 37 | 2.52 | 2.0 | 21.64 | 1846.1 |
| 1 X 240 | 61 | 2.25 | 2.2 | 24.65 | 2416.5 |
| 1 X 300 | 61 | 2.52 | 2.4 | 27.48 | 3023.6 |
| 1 X 400 | 61 | 2.85 | 2.6 | 30.85 | 3851.7 |
H07V-K Specification
| 450/750V,Copper Conductor PVC Insulated Flexible Wire | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No. | Diameter | mm | mm | kg/km |
| 1 X 1.5 | 30 | 0.25 | 0.7 | 3.00 | 20.6 |
| 1 X2.5 | 49 | 025 | 0.8 | 3.70 | 32.2 |
| 1 X4.0 | 56 | 0.30 | 0.8 | 4.21 | 48. |
| 1 X6.0 | 84 | 0.30 | 0.8 | 5.57 | 71.2 |
| 1 X10 | 84 | 0.40 | 1.0 | 7.30 | 124.4 |
| 1 X 16 | 126 | 0.40 | 1.0 | 8.00 | 175.8 |
| 1 X 25 | 196 | 0.40 | 1.2 | 10.10 | 272.5 |
| 1 X 35 | 276 | 0.40 | 1.2 | 11.87 | 373.9 |
| 1 X 50 | 396 | 0.40 | 1.4 | 13.93 | 532.8 |
| 1 X 70 | 360 | 0.50 | 1.4 | 16.12 | 737.9 |
| 1 X 95 | 475 | 0.50 | 1.6 | 19.24 | 978.1 |
| 1 X 120 | 608 | 0.50 | 1.6 | 19.95 | 1222.5 |
| 1 X 150 | 756 | 0.50 | 1.8 | 23.34 | 1529.7 |
| 1 X 185 | 925 | 0.50 | 2.0 | 25.54 | 1870.1 |
| 1 X 240 | 1221 | 0.50 | 2.2 | 27.85 | 2443.4 |
| 1 X 300 | 1525 | 0.50 | 2.4 | 32.49 | 3032.9 |
| 1 X 400 | 2013 | 0.50 | 2.6 | 35.35 | 3958.6 |
HO3VV-F and AO3VV-F Specification
| Rated Voltage | Copper Conductor PVC Insulated PVC Sheathed Round Flexible Connecting Wire | ||||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | PP Tape | Sheath Thickness | Overall Diameter | Approx. Net Weight | |
| mm2 | No./mm | mm | No./mm | mm | mm | kg/km | |
| 300/300V | 2 X0.5 | 16/0.20 | 0.5 | 1/0.05 | 0.6 | 5.87 | 34.80 |
| 2 X 0.75 | 24/0.20 | 0.5 | 1/0.05 | 0.6 | 6.50 | 43.40 | |
| 3 X 0.5 | 16/0.20 | 0.5 | 1/0.05 | 0.6 | 6.22 | 44.01 | |
| 3 X 0.75 | 24/0.20 | 0.5 | 1/0.05 | 0.6 | 6.90 | 55.64 | |
| 300/500V | 2 X 0.5 | 16/0.20 | 0.6 | 1/0.05 | 0.7 | 5.78 | 36.69 |
| 2 X 0.75 | 24/0.20 | 0.6 | 1/0.05 | 0.8 | 6.78 | 47.02 | |
| 2 X 1.0 | 32/0.20 | 0.6 | 1/0.05 | 0.8 | 6.78 | 54.79 | |
| 2 X 1.5 | 30/0.25 | 0.7 | 1/0.05 | 0.8 | 7.71 | 72.31 | |
| 2 X 2.5 | 49/0.25 | 0.8 | 1/0.05 | 0.8 | 9.51 | 111.90 | |
| 3 X 0.5 | 16/0.20 | 0.6 | 1/0.05 | 0.7 | 6.11 | 46.72 | |
| 3 X 0.75 | 24/0.20 | 0.6 | 1/0.05 | 0.8 | 6.74 | 59.71 | |
| 3 X 1.0 | 32/0.20 | 0.6 | 1/0.05 | 0.8 | 7.17 | 71.03 | |
| 3 X 1.5 | 30/0.25 | 0.7 | 1/0.05 | 0.8 | 8.17 | 95.26 | |
| 3 X 2.5 | 49/0.25 | 0.8 | 1/0.05 | 1.2 | 10.48 | 156.81 | |
| 3 X 4.0 | 50/0.30 | 0.8 | 1/0.05 | 1.2 | 11.38 | 199.81 | |
| 4 X 1.0 | 32 X 0.20 | ||||||
| 4 X 1.5 | 48 X 0.20 | ||||||
| 4 X 2.5 | 77 X 0.20 | ||||||
| 4 X 4.0 | 56 X 0.30 | ||||||
| 4 X 6.0 | 84 X 0.30 | ||||||
| 4 X 10 | 84 X 0.40 | ||||||
| 4 X 16 | 126 X 0.40 | ||||||
| 5 X 1.5 | 48 X 0.20 | ||||||
| 5 X 2.5 | 77 X 0.20 | ||||||
| 5 X 4.0 | 56 X 0.30 | ||||||
| 5 X 6.0 | 84 X 0.30 | ||||||
| 5 X 10 | 84 X 0.40 | ||||||
| 5 X 16 | 126 X 0.40 | ||||||
H03VVH2-F Specification
| 300/500V,Copper Conductor PVC Insulated PVC Sheathed Flat Wire | |||||
| Nominal Cross Section | Conductor Construction | Insulation Thickness | Sheath Thickness | Overall Diameter | Approx. Net Weight |
| mm2 | No./mm | mm | mm | mm x mm | kg/km |
| 2 X 0.75 | 1/0.97 | 0.6 | 0.9 | 3.97 x 6.14 | 39.0 |
| 2 X 1.0 | 1/1.13 | 0.6 | 0.9 | 4.13 x6.46 | 45.6 |
| 2 X1.5 | 1/1.37 | 0.7 | 0.9 | 4.57x7.34 | 60.5 |
| 2 X2.5 | 1/1.76 | 0.8 | 1.0 | 5.36x8.72 | 89.9 |
| 2 X4 | 1/2.24 | 0.8 | 1.0 | 5.84x9.68 | 123.5 |
| 2 X4 | 7/0.85 | 0.8 | 1.0 | 6.15x10.30 | 130.6 |
| 2 X6 | 1/2.74 | 0.8 | 1.1 | 6.54x10.88 | 169.4 |
| 2 X6 | 7/1.04 | 0.8 | 1.1 | 6.92x11.64 | 179.2 |
| 2 X10 | 7/1.35 | 1.0 | 1.2 | 9.45x14.50 | 286.5 |
| 2 X16 | 7/1.70 | 1.0 | 1.2 | 9.50x16.60 | 412.3 |
| 3 X0.75 | 1/0.97 | 0.6 | 0.9 | 3.97x8.31 | 55.2 |
| 3 X1.0 | 1/1.13 | 0.6 | 0.9 | 4.13x8.79 | 65.0 |
| 3 X1.5 | 1/1.38 | 0.7 | 0.9 | 4.58x10.14 | 87.7 |
| 3 X2.5 | 1/1.76 | 0.8 | 1.0 | 5.36x12.08 | 129.9 |
| 3 X4 | 1/2.24 | 0.8 | 1.1 | 6.04x13.72 | 184.7 |
| 3 X 4 | 7/0.85 | 0.8 | 1.1 | 6.35x14.65 | 195.4 |
| 3 X6 | 1/2.74 | 0.8 | 1.1 | 6.54x15.22 | 247.7 |
| 3 X 6 | 7/1.04 | 0.8 | 1.1 | 6.92x16.36 | 262.0 |
| 3 X10 | 7/1.35 | 1.0 | 1.2 | 8.45x20.55 | 420.8 |
| Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
| Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit mm | |||
| 0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
| 1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
| 1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
| 1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
| 2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
4.Package:
Packing in plastic reel, paper reel ,wooden drum or as customer's requirement.
5.Our factory:
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
6.Certificate:
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
7.Customer Visit:
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
8.Contact:
Dear friends, welcome to our store. We will provide you with china wholesale market market products, excellent service and reasonable price.Please contact us if have any questions about the product. we will answer the questions carefully.At last,I wish you a pleasant purchase.
Factrory ADD:No.13th,YongDing Road, Goingyi,Zhengzhou city, Henan province, China.
Send your message to this supplier
People who liked this also liked